2.3 Flood
2.3.1 All or parts of the following design flood results at dam(plant)sites shall be provided as required for the design of hydropower stations:
1 Annual maximum peak discharges of design floods with different frequencies and their maximum volumes in a period of time.
2 Seasonal maximum flood peak discharge and flood volume in a period of time by each design flood frequency.
3 Annual and seasonal design flood hydrographs by each design flood frequency.
2.3.2 The computation method for a design flood shall be properly chosen based on the data available in the region where the hydropower station is located.
If more than 30 years of actually measured and interpolated flood data is available for the dam(plant)site or at the upstream and downstream nearby locations,the frequency analysis method shall be employed to calculate the design flood.
If there is no flood data for the hydropower station region,but precipitation data is available,the design flood may be derived from the design rainstorm by analyzing the rainstorm frequency.
2.3.3 Design flood may be derived based on comprehensive analysis of the region by using flood and rainstorm data actually measured or investigated in the vicinity of the hydropower station,in case that the actually measured flood and rainstorm data for the region of the hydropower station is limited.The design flood may also be derived from the design rainstorm based on the research results on rainstorm and runoffgeneration-and-concentration areas with the matching Rainstorm Runoff Calculation Charts nationwide or in provinces,autonomous regions and municipalities directly under the Central Government that have been approved by the competent authorities.
2.3.4 When deriving design flood from design rainstorm,design rainstorms of different durations may be calculated by using the design spot rainstorm and the spot-area relationship.The design spot rainstorm may be calculated from the approved isoline map of rainstorm statistic parameters.Temporal distribution of the design rainstorm may be obtained by amplifying design rainstorms in different durations with same frequency based on the region's comprehensive rainfall pattern or a typical rainfall pattern.
The duration of design rainstorm may be 24h or defined according to the basin area and duration of flow concentration.
Parameters of runoff-generation-and-concentration to derive design flood from design rainstorm may be found on the approved rainstorm runoff calculation chart.
2.3.5 Parameters and calculation results used in the computation of design flood shall be analyzed and examined in multiple ways to demonstrate rationality of the results.
2.3.6 For historical floods to be adopted in the computation of design flood,the historical flood investigation results that have been promulgated by the authorities of provinces(autonomous regions or municipalities directly under the Central Government)may be quoted directly.If actually measured data or investigated historical flood data is unavailable for the river where the hydropower station is located,investigations regarding historical floods shall be carried out at the dam(plant)site or at its upstream and downstream reaches.
2.3.7 In the computation of stage design flood,the stage shall be defined according to design requirements of the project,and the starting and ending dates shall comply with the pattern of changes in flood season.The stage should not be shorter than one month.The stage design flood may be used at cross-stage.
2.3.8 If there is a regulating storage reservoir upstream of the hydropower station,the regional composition of design flood shall be studied,and the design flood at the dam site under the impact of the water storage and regulation of the upstream reservoir be derived.
- GB/T 50381-2018 城市軌道交通自動售檢票系統(tǒng)工程質(zhì)量驗收標準
- DL/T5161.1-2002電氣裝置安裝工程質(zhì)量檢驗及評定規(guī)程第1部分:通則(英文版)
- GB50542-2009石油化工廠區(qū)管線綜合技術(shù)規(guī)范(英文版)
- DL/T5161.3-2002電氣裝置安裝工程質(zhì)量檢驗及評定規(guī)程第3部分:電力變壓器、油浸電抗器、互感器施工質(zhì)量檢驗(英文版)
- 巖土靜力載荷試驗規(guī)程
- GB50580-2010連鑄工程設(shè)計規(guī)范(英文版)
- GB 50169-2016 電氣裝置安裝工程 接地裝置施工及驗收規(guī)范
- GB/T 51243-2017 物聯(lián)網(wǎng)應用支撐平臺工程技術(shù)標準
- 換流站接地極設(shè)計文件內(nèi)容深度規(guī)定
- GB 51284-2018 煙氣脫硫工藝設(shè)計規(guī)范
- 電力系統(tǒng)無功補償及調(diào)壓設(shè)計技術(shù)導則
- GB/T 51223-2017 公共建筑標識系統(tǒng)技術(shù)規(guī)范
- DL/T 5504-2015 特高壓架空輸電線路大跨越設(shè)計技術(shù)規(guī)定
- GB 50372-2006 煉鐵機械設(shè)備工程安裝驗收規(guī)范 (英文版)
- GB/T 51325-2018 煤焦化粗苯加工工程設(shè)計標準