4.7 Transmission-related Ancillary Technologies
4.7.1 The dispersion compensation design of a WDM digital transmission system shall be in accordance with the following requirements:
1 An incoherent detection repeaterless WDM digital transmission system may perform pre-dispersion compensation at the transmitter and post-dispersion compensation at the receiver;dispersion compensation may be fixed dispersion compensation and/or self-adaptive dispersion compensation;and the two may be combined to achieve precise single-channel dispersion compensation.
2 An incoherent detection repeatered WDM digital transmission system may perform its dispersion compensation through a combination of evenly distributed dispersion-compensation spans along the cable line and the compensation mechanism of terminal equipment described in Item 1of this clause.
4.7.2 The design of an incoherent detection WDM digital transmission system shall take into consideration the impact of PMD,and the DGD penalty shall be within the tolerance of the performance budget.
4.7.3 The application of power equalization technologies shall comply with the following principles:
1 For a reperterless WDM digital transmission system,the SLTE shall have the function of optical power equalization,and single-channel power equalization may be performed automatically without personal involvement;
2 For a repeatered WDM digital transmission system,power equalization may be achieved by combining the installation of gain equalizers along the cable line and the optical power equalization of the terminal equipment.
4.7.4 Based on the cost of submerged equipment,submarine digital transmission systems should adopt the state-of-the-art FEC,coding modulation,and receiver technologies.
4.7.5 According to the distance between landing stations and design capacity,repeaterless digital transmission systems may adopt pre-amplifiers,post-amplifiers,pre-remote EDF amplifiers,post-remote EDF amplifiers,or Raman amplifiers.
- GB/T 50537-2017 油氣田工程測量標準
- 設(shè)計系統(tǒng)發(fā)展研究
- 電力調(diào)度數(shù)據(jù)網(wǎng)絡(luò)工程設(shè)計規(guī)程
- GB/T51075-2015選礦機械設(shè)備工程安裝規(guī)范(英文版)
- DL/T 5546-2018 自然通風冷卻塔防腐設(shè)計導則
- DL/T5161.3-2002電氣裝置安裝工程質(zhì)量檢驗及評定規(guī)程第3部分:電力變壓器、油浸電抗器、互感器施工質(zhì)量檢驗(英文版)
- GB/T 50643-2018 橡膠工廠職業(yè)安全衛(wèi)生設(shè)計標準
- GB50764-2012電廠動力管道設(shè)計規(guī)范(英文版)
- DL/T 5156.1-2015 電力工程勘測制圖標準 第1部分:測量
- GB 51133-2015 醫(yī)藥工業(yè)環(huán)境保護設(shè)計規(guī)范
- GB 50360-2016 水煤漿工程設(shè)計規(guī)范
- DL/T5232-2010±800kV及以下直流換流站電氣裝置安裝工程施工及驗收規(guī)程(英文版)
- GB/T 51189-2016 火力發(fā)電廠海水淡化工程調(diào)試及驗收規(guī)范
- GB50397-2007冶金電氣設(shè)備工程安裝驗收規(guī)范(英文版)
- GB/T 51325-2018 煤焦化粗苯加工工程設(shè)計標準